Replaces
Schneider ATV12
Candidate replacement, subject to engineering review.

KV4500 VFD
The Kemron KV4500 is a compact VFD whose official manual lists 0.75–2.2 kW 220 V-class models and 0.75–7.5 kW 380 V-class models. It supports sensorless-vector and V/F control for AC induction or permanent-magnet synchronous motors, four digital inputs, and Modbus RTU over RS485. Selection remains subject to engineering review, with the exact rating, wiring, motor data, braking, and commissioning scope confirmed at RFQ.

Lead time confirmed within 1 business day
1business day first reply
Schneider ATV12
Candidate replacement, subject to engineering review.
| Manual Listed Models 220v | KV4500-0.75G-2S, KV4500-1.5G-2S, KV4500-2.2G-2S |
|---|---|
| Manual Listed Models 380v | KV4500-0.75G-4T, KV4500-1.5G-4T, KV4500-2.2G-4T, KV4500-4.0G-4T, KV4500-5.5G-4T, KV4500-7.5G-4T |
| Manual Listed Power Range 220v | 0.75–2.2 kW |
| Manual Listed Power Range 380v | 0.75–7.5 kW |
| Supply Wiring | 220 V: connect L1 and L3, leave L2 open; 380 V: connect L1, L2 and L3 |
| Control Modes | Sensorless vector control (00-01=0); V/F control (00-01=2, default) |
| Motor Compatibility | AC induction motor (00-08=0); permanent-magnet synchronous motor (00-08=1) |
| Maximum Operating Frequency | 350.00 Hz with 0.01 Hz unit; 3500.0 Hz with 0.1 Hz unit |
| Carrier Frequency | 0.5–15.0 kHz |
| Digital Inputs | 4 × DI (DI1–DI4) |
| Analog Input | 1 × AI terminal |
| Analog Output | 1 × AO terminal |
| Relay Output | 1 × relay output (TA/TC terminals) |
| Communication | RS485; Modbus RTU slave protocol |
| Modbus Default | 9600 bps, 8N2, address 1 |
| Dimensions 0 75 To 2 2kw | 72.2 × 161.47 × 136.8 mm |
| Dimensions 4 0 To 7 5kw | 89 × 198.5 × 169.6 mm |
| Model number | KV4500 |
|---|---|
| Brand | Kemron |
| Category | VFD Drives |
| Availability | Typically in stock, quantity and lead time confirmed at RFQ |
The manual lists 220 V-class models from 0.75 to 2.2 kW and 380 V-class models from 0.75 to 7.5 kW. The exact order code and rating are confirmed at RFQ.
The official parameter table lists AC induction and permanent-magnet synchronous motors, with sensorless-vector control and V/F control.
Yes. The manual lists an RS485 interface with Modbus RTU slave communication. The published default is 9600 bps, 8N2, address 1.
Send the application, quantity and target date. We will check fit and availability.
We check the motor, supply, load, braking and protocol before selecting the KV4500.
The official KV4500 manual lists 0.75–2.2 kW 220 V-class and 0.75–7.5 kW 380 V-class variants
the public product page states a wider 0.4–2.2 kW / 0.4–15 kW range, so this record uses the narrower manual-listed variants pending manufacturer reconciliation
The Schneider ATV12 anchor is category-level only — voltage, current, overload, braking and enclosure fit remain subject to engineering review
SoMove parameter files and Schneider terminal conventions do not transfer — full recommissioning applies
A line-by-line BOM review checks the whole list against the application before it becomes an order.